Frequenzumrichterserie firmwareversion 1561 swversion option gsdmldatei fc102 fc 202 fc 302 1. It usually comes up during startup, if the vfd has an communications option card bacnet and no communications connected. Predrilled adaptor plates make it easy to mount a new fc 302 in place of a vlt 5000. Safe stop installation fc 302 and fc 301 a1 enclosure only. If you have questions about how to set up master master communication or communication to a nondanfoss slave, please consult the appropriate documentation. Vlt fc 102, vlt fc 103, vlt fc 202, vlt fc 301, vlt fc 302. Manual danfoss fc302 power inverter electric motor scribd. Communication using profibus dpv1, master class 1, and master class 2. Read and follow the operating instructions in order to use the frequency converter safely and professionally, and pay particular attention to the safety instructions and general warnings.
The vlt profibus dp mca 101 programming guide provides information about configuring the system, controlling the frequency converter, parameter access, programming, troubleshooting, and some typical application examples. Danfoss ac frequency inverter for 15kw 20hp 400v 3 phase motor. How to control the fc102fc 202fc301 fc302 how to access fc102fc 202fc301 fc302 parameters parameters troubleshooting terminology. The vlt automation drive fc302 is a robust, reliable and powerful variable speed drive designed to work with all asynchronous motors and permanent magnet motors. It is also assumed that you are using a plc or pc, as a master, that is equipped with a serial. However, the frequency converter says wrong configuration. New protocol extensions retain all the functions of the previous versions. May, 2014 as i read in the describtion of danfoss fc302, it is not a pndevice and the additional interfaces are aoptionen mca 101 profibus dpv1 mca 102 devicenet mca 121 ethernetip mca 1 vlt 3000 profibus konverter mca 122 modbus tcp. The operating instructions are intended for use by qualified personnel. To determine software version refer to parameter 603, name plate. Danfoss fc302 profinet 800xa engineering control builder m. The software version number can be seen from parameter 1543 software version. Danfoss electronics fc302 series ac drives in stock at galco. I have problems with the profinet comunication to danfoss vlt fc302.
The standard is supported by the member companies of the profibus international user community. Profibus gsd database search results for fc302 danfoss. Programming guide vlt automationdrive fc 302 danfoss. Vlt devicenet mca 104 offers robust, efficient data handling thanks to advanced producerconsumer technology. Danfoss fc302 profinet 800xa engineering control builder. Does somebody know if there are some website to download the function block for it. I want to control a danfoss fc302 with s71500 plc through profinet. Cse industrial electrical distributors supplies a range of danfoss drives including the danfoss vlt automationdrive fc 301 fc301 a1 and fc 302 drives this is a handy comparison, fc301, fc302, danfoss fc 301, danfoss fc 302. View and download danfoss vlt automationdrive fc 302 operating instructions manual online. The software version number can be found in parameter 1543. Programmierhandbuch vlt profibus dp mca 101 frequenzumrichter. Danfoss vlt inverter drive fc 302 compared to fc 301 a1. Download free danfoss fc302 programming manual danfoss fc302 programming manual as recognized, adventure as competently as experience about lesson, amusement, as competently as deal can be gotten by just checking out a books danfoss fc302 programming manual as well as it is not directly done, you could acknowledge even more just about this life, approximately.
The programming guide is intended for use by qualified personnel familiar with the vlt frequency converter, with. Search thousands of gsd files by ident number, vendor, and model name. It helps save energy, increase flexibility, reduce costs related to spare parts and servicing, and. A manual initialization also resets serial communication. Supplementary publications and manuals are available. Danfoss offer a free, downloadable drive conversion wizard so you can move your parameters and convert your vlt5000 or vlt6000 parameters to the latest generation fc 302 drives with a simple click of a button. Largest profibus gsd general station description file database in the world. Profinet, is the term used to describe the profinet protocol. Touching the electrical parts, even when the ac line has been disconnected. The profibus interface enables communication between a vlt frequency converter and any master complying with the profibus standard. Het koppelen van een fc302 op profibus met een siemens plc. Consequently, the instructions in this manual, as well as national and. Danfoss vlt automationdrive fc 302 official distributor. Vlt profibus dp mca 101 danfoss vlt profibus dp mca 101 is intended for use with.
Input voltage 380500v three phase 10% at 5060hz 5%. The actual software version number can be read from parameter 1543 software version. Odvas ac drive profile supported using io instance 2070. The danfoss advanced harmonic filters have been specially designed to match the danfoss frequency converters. Communication can be configured via mct 10 setup software. By the use of this process we ensure that not only the correct language but the very latest version of the manual is always produced and shipped with the correct drive. Keep these operating instructions available with the frequency converter at all times. Danfoss vlt automationdrive fc 302 operating instructions manual. View and download danfoss fc 300 profibus manual online. Vlt profibus dp mca 101 media converter pdf manual download. Vlt automationdrive fc 302 dc drives pdf manual download. Programming manual, design manual, operating instructions manual, instruction manual, installation manual.
Supplementary publications and manuals are available from danfoss. Danfoss vlt automationdrive fc 301 manuals manuals and user guides for danfoss vlt automationdrive fc 301. Esv222n02yxb lenze ac tech vfd drive inverter valin. Users are assumed to be familiar with the vlt frequency converter, with profibus technology, and with. We have 23 danfoss vlt automationdrive fc 301 manuals available for free pdf download. Danfoss fc302 ip20 15kw 400v 3ph ac inverter drive with. The wellstructured menu system ensures fast commissioning and easy access to. The vlt automationdrive fc 300 profibus instruction manual provides the information.
It comes in a standard version fc 301 and an advanced high dynamic version fc 302 with additional functionalities. The profinet name and ethernet parameters ip, mask, etc. I have configured the module in control builder with the latest version of gsdml file gsdmlv2. This is crucial for applications where preventing uninteded starts are of vital importance. Vlt 2800fcd 300 devicenet contents introduction danfoss. After a couple of minutes without communications, you will get fieldbus fault w34, a comm failure on the card. The frequency converter prov ides full short circuit protection in case of a shortcircuit on the motor or brake output. Danfoss fc302 ip20 22kw with profibus 380v500v 3ph ac. Assumptions this manual assumes that you are using a danfoss vlt 2800 or fcd 300 unit with devicenet. Danfoss vlt ac frequency inverter for 22kw 29hp 400v 3 phase motor in vxf control. Ip protection class ultype ip21type 1 ip55type 12 ip54type 12 ip66type 4x. The installation guide is intended for use by qualified personnel. Acyclic parameterization using profibus dpv1, profidrive or danfoss fc profile state machines, profibus dpv1, master class 1 and 2.
Danfoss ac drives fc302 programming guide galco industrial. Contents 1 safety 2 mechanical installation 3 electrical. The vlt automationdrive fc 302 comes standard with safe stop functionality suitable for category 3 installations as defined by en 9541. Learn how to start up your danfoss vlt automationdrive using the award winning easytouse local control panel lcp. Call us for more info you want to run a sequence like this. For information about profibus and downloads for profibus dp and the profidrive profile, refer to. The vlt automationdrive is designed for variable speed control of all asynchronous motors and permanent magnet motors. Engineering tomorrow programming guide vlt automationdrive fc 302 software versions, control card mk ii. Vlt automationdrive fc 302 vltdrives contents 1 introduction 3 1. The intent of warning 34 is that if you lost communications on the card you could trigger certain events stopfull speedpreset speed things you might want to do if comm went down and you lost control of the vfd. Once the drive is shipped, one of more than 60 local danfoss sales.
Pdf danfoss fc302 profibus handbuch,vlt profibus dp mca 101,danfoss vlt 5000 bedienungsanleitung,danfoss vlt 5000 manual,danfoss vlt 5000 preis,danfoss fc302 profinet handbuch,danfoss fc 300 profibus,danfoss fehlercodeliste, vlt 50005000 flux6000 simple connect danfoss vlt to siemens s71200 over profinet. Nov 06, 2014 learn how to start up your danfoss vlt automationdrive using the award winning easytouse local control panel lcp. Danfoss recommends using the fuses mentioned in the following tables to protect service personnel or other equipment in case of an internal failure in the unit or shortcircuit on dclink. Sep 17, 2014 20051002 drives division flemming huusmannddspmp confidential property of danfoss drives as 5 profibus terms profibus l2 nonnorm profibus about 1700 vlt 3000 produced with l2, 1992 1994 up to ver. Gsd files you could find in website of danfoss, i suppose see attachment as well danfoss. Programming guide vlt profibus dp mca 101 vlt frequency converter series fc 102 fc 103 fc 202 fc 302 fcd 302 fcp 106 fcm 106. Vlt aqua drive fc 202, vlt automationdrive fc 302, vlt hvac drive fc 102, vlt decentral drive fcd. Can somebody give a example of this vlt profinet mca 120 dc drives pdf manual download. Iec en618003 class a1b category c1 industrial and domestic. Programming manual 346 pages design manual 212 pages instruction manual 174 pages. Programming guide vlt automationdrive fc 302 software. Making modern living possible programming guide vlt profibus dp mca 101 vlt frequency converter series fc 102 fc 103 fc 202 fc 302 fcd 302 fcp 106 fcm 106 vltdrives. Fc 302 can handle 3 types of kty sensors, defined in. Profibus dp v1 profinet powerlink devicenet canopen modbus tcp ethernetip ethercat.
38 325 925 1574 197 310 789 423 1404 1510 523 1534 1106 1304 152 1024 319 268 1177 248 232 393 1112 1478 313 792 795 779 404 1126 1061 1046 1622 1149 1377 1329 543 368 586 547 893 427 226 363